Determination of 4-nonylphenol in carp blood samples by solid phase extraction and chromatographic techniques

Author: Gadzała-Kopicuch R.  

Publisher: Taylor & Francis Ltd

ISSN: 0277-2248

Source: Toxicological and Environmental Chemistry, Vol.89, Iss.3, 2007-07, pp. : 443-453

Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.

Previous Menu Next

Abstract

In this study, selective methods were developed for isolation, purification, separation and determination of 4-nonylphenol (4NP) in biological samples. Several methods such as high-performance liquid chromatography (HPLC) with fluorescence and diode array detection and gas chromatography coupled to mass spectromotry (GC-MS) are described for the simultaneous determination of 4NP. The nonylphenols in the plasma of fish were extracted through solid phase process by using octadecyl, polymeric and octadecyl endcapping sorbents. The average recoveries in plasma samples spiked with 4NP of levels 1 µg mL-1 were between 80-95% using added surrogate standards. The aim of this study was to determine whether trace amounts of 4NP in fish plasma samples could be detected by solid phase extraction and chromatographic methods (HPLC, GC-MS). This technique of monitoring the levels of endocrine-disruptors in plasma samples is consistent, reliable as well as inexpensive.

Related content