Author: Zhang L.
Publisher: Taylor & Francis Ltd
ISSN: 1521-0480
Source: Experimental Heat Transfer, Vol.20, Iss.3, 2007-07, pp. : 251-260
Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.
Abstract
The nucleate pool boiling heat transfer data on a smooth flat surface were measured for three binary mixtures of HC600a/HFC134a, HC600a/HC290, and HC600a/HFC23. Much effort was made to investigate the influence of the boiling range on the pool-boiling heat transfer performance. From the experimental results, the HC600a/HFC23 mixture with a wide boiling range showed lower heat transfer coefficients (HTCs) than the mixture with a narrow boiling range such as HC600a/HFC134a and HC600a/HC290 systems. The measured data were also compared with the results predicted by five well-known correlations. It can be found that the average deviation is less than 25% for mixtures with narrow boiling ranges, but a larger deviation for mixtures with wide boiling ranges.
Related content


The influence of oil on nucleate pool boiling heat transfer
Heat and Mass Transfer, Vol. 45, Iss. 7, 2009-05 ,pp. :