Author: Ho Chii-Dong Huang Jun-Wei Tu Jr-Wei
Publisher: Taylor & Francis Ltd
ISSN: 1521-0634
Source: Numerical Heat Transfer Part A: Applications, Vol.54, Iss.7, 2008-01, pp. : 709-725
Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.
Abstract
This research studies the heat transfer characteristic of an unsteady close-contact melting on a flat plate in the cool-thermal discharge systems with external recycle, develops the mathematical model theoretically to simulate the conduction-convection heat-transfer phenomena, and calculates the theoretical prediction of the outlet chilled air temperature by solving the energy balance associated with integral boundary-layer analysis. It is found that the recycle effect can enhance the average Nusselt numbers and heat-transfer efficiency improvement effectively. Three numerical examples of inlet ambient air temperature are illustrated to compute the chilled air temperature, average Nusselt numbers and heat-transfer efficiency with three specified volumetric flow rate and three traversed length of the ambient inlet air as parameters.
Related content


By Ho Chii-Dong
Numerical Heat Transfer Part A: Applications, Vol. 46, Iss. 3, 2004-08 ,pp. :


Numerical Heat Transfer Part A: Applications, Vol. 50, Iss. 9, 2006-12 ,pp. :


By Ho Chii-Dong Yeh Ho-Ming Su Ying-Sian
Numerical Heat Transfer Part A: Applications, Vol. 45, Iss. 5, 2004-03 ,pp. :




Heat transfer effect on the performance of MHD power plant
By Chen L. Gong J. Sun F. Wu C.
Energy Conversion and Management, Vol. 43, Iss. 15, 2002-10 ,pp. :