Publisher: Academic Press
ISSN: 0022-460X
Source: Journal of Sound and Vibration, Vol.193, Iss.4, 1996-06, pp. : 773-792
Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.
Abstract
The purpose of this study is to show the effectiveness of control strategies among the passive tuned mass damper system, active tuned mass damper (ATMD) system, base-isolation system and hybrid control system. A systematic way to determine the weighting matrix Q in the control system is proposed. The weighting matrix Q used in the ATMD system is determined by estimating the gain of modal control through the pole assignment method. For the hybrid control system discussion on the weighting matrix Q is also presented. Numerical studies using different control strategies on two buildings (one is a stiff structure and the other is a soft structure) are discussed.
Related content








On the optimization of a hybrid tuned mass damper for impulse loading
Smart Materials and Structures, Vol. 24, Iss. 8, 2015-01 ,pp. :