Development and Use of a Simple Polymerase Chain Reaction Assay to Screen for Helicobacter spp. and H. hepaticus in Intestinal and Fecal Samples from Laboratory Mice

Author: Fermér Christian   Lindberg Anna V.   Feinstein Ricardo E.  

Publisher: American Association for Laboratory Animal Science

ISSN: 1532-0820

Source: Comparative Medicine, Vol.52, Iss.6, 2002-12, pp. : 518-522

Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.

Previous Menu Next

Abstract

A simple and sensitive duplex polymerase chain reaction (PCR) assay was developed for use in detection of Helicobacter species and H. hepaticus in laboratory mice. Bacteria were extracted and concentrated from fecal pellets and intestinal segments by use of buoyant density centrifugation. To improve quality assurance, an internal control (mimic) for detection of false-negative reactions was included. In addition, cartridges (Capillette) pre-filled with PCR reagents, were used to minimize the hands-on time required, thus reducing the risk of contamination with previously amplified material. Laboratory mice from Swedish animal houses sent to the National Veterinary Institute for health monitoring were found to have high prevalence of H. hepaticus.