

Author: Zhuang Ziqing Coffey Christopher Ann Roland
Publisher: Taylor & Francis Ltd
ISSN: 1545-9624
Source: Journal of Occupational and Environmental Hygiene, Vol.2, Iss.12, 2005-12, pp. : 641-649
Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.
Abstract
A recent study was conducted to compare five fit test methods for screening out poor-fitting N95 filtering-facepiece respirators. Eighteen models of NIOSH-certified, N95 filtering-facepiece respirators were used to assess the fit test methods by using a simulated workplace protection factor (SWPF) test. The purpose of this companion study was to investigate the effect of subject characteristics (gender and face dimensions) and respirator features on respirator fit. The respirator features studied were design style (folding and cup style) and number of sizes available (one size fits all, two sizes, and three sizes). Thirty-three subjects participated in this study. Each was measured for 12 face dimensions using traditional calipers and tape. From this group, 25 subjects with face size categories 1 to 10 tested each respirator. The SWPF test protocol entailed using the PortaCount Plus to determine a SWPF based on total penetration (face-seal leakage plus filter penetration) while the subject performed six simulated workplace movements. Six tests were conducted for each subject/respirator model combination with redonning between tests. The respirator design style (folding style and cup style) did not have a significant effect on respirator fit in this study. The number of respirator sizes available for a model had significant impact on respirator fit on the panel for cup-style respirators with one and two sizes available. There was no significant difference in the geometric mean fit factor between male and female subjects for 16 of the 18 respirator models. Subsets of one to six face dimensions were found to be significantly correlated with SWPFs (p
Related content






Correlation Between Respirator Fit and Respirator Fit Test Panel Cells by Respirator Size
By Zhuang Ziqing Groce Dennis Ahlers Heinz Iskander Wafik Landsittel Douglas Guffey Steve Benson Stacey Viscusi Dennis Shaffer Ronald
Journal of Occupational and Environmental Hygiene, Vol. 5, Iss. 10, 2008-10 ,pp. :


Development of an Advanced Respirator Fit-Test Headform
By Bergman Michael S. Zhuang Ziqing Hanson David Heimbuch Brian K. McDonald Michael J. Palmiero Andrew J. Shaffer Ronald E. Harnish Delbert Husband Michael Wander Joseph D.
Journal of Occupational and Environmental Hygiene, Vol. 11, Iss. 2, 2014-02 ,pp. :