Shipboard Power Systems Design and Verification Fundamentals

Chapter

1.5 Shipboard Electrical System Design Verification and Validation (V&V)

1.5.1 Verification and Validation (V&V) Overview

1.5.2 Verification

1.5.2a Acceptance of Verification

1.5.3 Validation

1.5.4 Differences Between Verification and Validation: Shipboard Electrical System Design and Development Process

1.6 IEEE 45 Dot Standards: Recommended Practice for Shipboard Electrical Installation

1.7 Other Rules and Regulations, and Standards in Support of IEEE 45 Dot Standards

1.8 Shipboard Ungrounded Power System

1.9 Shipboard Electrical Design Basics

1.10 Electrical Design Plan Submittal Requirements

USCG Code of Federal Regulations CFR 46 Part 110

1.11 ABS Rules for Building and Classing Steel Vessels

1.12 Shipboard Electrical Safety Considerations

1.13 High-Resistance Grounding Requirements for Shipboard Ungrounded Systems (See Chapter 9 for Details)

(a) Background of High-Resistance Grounding (HRG) with Maximum Fault Current 5 Amp RMS

1.14 Shipboard Electrical Safety Considerations

1.14.1 Arc Flash Basics (See Section 12 for Details)

1.14.2 Arc Flash Hazard Analysis Procedures

1.14.3 Warning Label Placement

1.15 Propulsion Power Requirements (IEEE Std 45-2002, Clause 7.4.2)

1.16 IMO-Solas Electric Propulsion Power Redundancy Requirements

1.17 Regulatory Requirements for Emergency Generator

1.18 USCG Dynamic Positioning (DP) Guidelines

DNV Part 4, Chapter 8

1.19 IEC/ISO/IEEE 80005-1-2012: Utility Connections in Port—High Voltage Shore Connection (HVSC) Systems—General Requirements

1.20 Mil Standard 1399 Medium Voltage Power System Characteristics

1.21 Shipboard Power Quality and Harmonics (See Chapter 7 for Detail Requirements)

1.21.1 IEEE Std 45-2002, Clause 4.6, Power Quality and Harmonics

1.21.2 Power Conversion Equipment-Related Power Quality

1.21.2a IEEE Std 45-2002, Clause 31.8, Propulsion Power Conversion Equipment (Power Quality)

1.22 USCG Plan Submittal Requirements

1.23 ABS Rules for Building and Classing Steel Vessels (Partial Listing)

1.24 Design Verification and Validation

1.24.1 Design Verification Test Procedure (DVTP)

1.24.2 Qualitative Failure Analysis (QFA)

1.24.3 IEEE 519 Harmonic Standard

1.25 Remarks for VFD Applications Onboard Ship

2 Electrical System Design Fundamentals and Verifications

2.0 Introduction

2.1 Design Basics

2.2 Marine Environmental Condition Requirements for the Shipboard Electrical System Design

2.3 Power System Characteristics: MIL-STD-1399 Power Requirements

2.4 ABS Type Approval Procedure (Taken From ABS Directives)

2.4.1 List of Recognized Laboratories

2.4.2 Nationally Recognized Testing Laboratory Program

2.4.3 Procedure for Becoming Type Approved

2.5 Shipboard Electrical Power System Design Basics

2.5.1 Table 2.4: Explanation for Note 1 of Figure 2.1 (Use of Multiple Options, Step Down Transformer, MG Set, PCU)

2.5.2 Table 2.5: Explanation for Note 2 of Figure 2.1 (Use of Power Conversion Unit to Supply Power from MV SWBD to the Ship Service SWBD)

2.5.3 Table 2.6: Explanation for Note 3 of Figure 2.1 (Use of Motor Generator with MV Input to AC Motor and Driving AC Generator)

2.5.4 Table 2.7: Explanation for Note 4 of Figure 2.1 (High-Power Battery Supplying Power to the 480 V Ship Service Switchboard)

2.5.5 Table 2.8: Explanation for Note 5 of Figure 2.1 (Use of Step Down Service Transformer to Supply Power from MV SWBD to the Ship Service SWBD)

2.5.6 Table 2.9: Explanation for Note 6 of Figure 2.1 (Variable Frequency of Adjustable Drive for Electrical Propulsion Application)

2.6 Shipboard Electrical Standard Voltages

2.6.1 NORSOK Standard 6.1 System Voltage and Frequency

2.7 Voltage and Frequency Range (MIL-STD-1399)

2.8 Ungrounded System Concept (ANSI and IEC)

2.9 Concept Design

2.9.1 Power Generation

2.9.2 Power Distribution

2.10 Design Features Outlined in

2.11 Protective Device–Circuit Breaker Characteristics

2.12 Fault Current Calculation and Analysis Requirement

2.12.1 Fault Current Calculation Fundamentals

2.13 Adjustable Drive Fundamentals

2.13.1 Advantages of ASD for Shipboard Application

2.13.2 Disadvantages of VFD/ASD for Shipboard Application

2.14 Fundamentals of ASD Noise Management

2.15 Electrical Noise Management (See Chapter 7 for Additional Details)

2.16 Motor Protection Solutions: DV/DT Motor Protection Output Filter

3 Power System Design, Development, and Verification

3.0 Introduction: Design, Development, and Verification Process

3.1 Typical Design and Development of Power Generation and Distribution (See Figure 3.1)

3.2 Failure Mode and Effect Analysis (FMEA): Design Fundamentals

3.2.1 Failure Mode and Effect Analysis (FMEA)

3.3 Failure Mode and Effect Analysis (FMEA) Electric Propulsion System Diesel Generator: Design Fundamentals

3.3.1 Diesel Engine Operational Mode Selection

3.3.2 Diesel Generator Safety System Functions

3.3.3 Power Management Overview Mimic (Central Control Station and Switchboard)

3.3.4 Power Distribution Mimic Page

3.4 Design Verification: General

3.4.1 Qualitative Failure Analysis (QFA)

3.4.2 Qualitative Failure Analysis (QFA) Basics

3.4.3 Process Failure Mode and Effect Analysis (FMEA): General

3.4.4 Qualitative Failure Analysis (QFA)-1

3.4.5 Explanation of the Detail Design Using QFA

3.4.6 Design Verification Test Procedure (DVTP): General

3.4.7 Example-1: Propulsion Plant (DVTP) Design Verification Test Procedure

3.5 Ship Service Power System Design: System-Level Fundamentals (Figure 3.2)

3.6 Single Shaft Electric Propulsion (Figure 3.3)

3.7 Electrical Generation and Distribution with Detail Design Information (Figure 3.4)

3.8 Electric Propulsion and Power Conversion Unit for Ship Service Distribution (Figure 3.5)

3.9 6600V and 690V Adjustable Speed Application with High-Resistance Grounding-1 (Figure 3.6)

3.10 MV and 690V Adjustable Speed Application with High-Resistance Grounding (Figure 3.7)

3.11 Fully Integrated Power System Design with Adjustable Speed Drive (Figure 3.8)

3.12 Variable Frequency Drive (VFD) Voltage Ratings and System Protection

Voltage Motor Insulation Stress when Driven by a Variable Frequency Drive

3.13 Example 460V, Three-Phase, Full Wave Bridge Circuit Feeding Into a Capacitive Filter to Create a 650 VDC Power Supply

3.14 Special Cable and Cable Termination Requirements for Variable Frequency Drive Application

3.15 Harmonic Management Requirements for Variable Frequency Drive Application

3.16 Switchgear Bus Bar Ampacity, Dimension, and Space Requirements

3.16.1 Bus Bar Rating for English Dimensions (Inches)

3.16.2 Bus Bar Rating for Metric Dimensions (Millimeter: MM)

3.16.3 Nominal Working Space Requirements

3.17 Meece (Management of Electrical and Electronics Control Equipment) Course Outline Requirements: USCG

4 Power Generation and Distribution

4.0 Introduction

4.1 Generation System Requirements

Generators

4.2 IEEE Std 45-2002, ABS-2002 and IEC for Generator Size and Rating Selection

4.3 ABS-2002 Section 4-8-2-3.1.3 Generator Engine Starting from Dead Ship Condition (Extract)

4.4 Additional Details of Sizing Ship Service Generators

4.4.1 Engine Governor Characteristics

4.4.2 Generator Voltage Regulator Characteristics

4.4.3 How AVR works:

4.4.4 Droop Characteristics: Generator Set

4.5 Typical Generator Prime Mover

Electric propulsion system (ABS R2 redundancy)

4.6 Generator: Typical Purchase Specification (Typical Electrical Propulsion System)

5 Emergency Power System Design and Development

5.0 Introduction

(a) Emergency Generation and Distribution

(b) Emergency No-Break Power Generation and Distribution

5.1 USCG 46 CFR Requirements: 112.05 (Extract Only)

5.2 IEEE STD 45-2002, Clause 6.1, General (Extract)

5.3 Emergency Source of Electrical Power: ABS 2010, 5.1.1 Requirement

5.4 ABS Emergency Generator Starting Requirement (ABS Rule for Passenger Vessels)

5.5 Typical Emergency Generation and Distribution System

5.6 Emergency Generator and Emergency Transformer Rating: Load Analysis (Sample Calculation)

5.7 Emergency Power Generation and Distribution with Ship Service Power and Distribution System

5.8 Emergency Transformer 450V/120V (Per ABS)

5.9 Emergency Generator Starting Block Diagram

5.10 Emergency Generation and Distribution Design Verification

5.11 No-Break Emergency Power Distribution

6 Protection and Verification

6.0 Introduction: Protection System Fundamentals

6.1 Protective Device: Glossary

6.2 Power System Protections

6.3 Power System: Procedure for Protective Device Coordination

6.4 Fault Current Calculation Guidelines (Per USCG Requirements)

111.52–3 Systems below 1500 Kilowatts

6.5 Overall Protection Synopsis

6.6 ANSI Electrical Device Numbering (for Device Number Details Refer to ANSI C.37.2)

ANSI 50N/51N or 50G/51G – Earth fault

6.7 Fault Current Calculations (Per USCG Requirements CFR 111-52-3(B) & (C))

6.7.1 Maximum Asymmetrical Fault Current

6.7.2 Average Asymmetrical Fault Current

6.7.3 450 V Switchboard Rating

6.7.4 450 V Switchboard Circuit Breaker Rating

6.7.5 Fault Current Calculation for the 120 Voltage System is as follows

6.7.6 RMS Symmetric Current

6.7.7 Fault Current Calculation Summary

6.8 Details for Figure 6.3 Typical EOL for MV Generator Protection System: Split Bus with Two Bustie Breakers

6.9 Details for Figure 6-4: Typical EOL for MV Generator Protection System: Split Bus with Two Bustie Breakers

6.10 Details for Figure 6.5 Typical for Transformer Protection Schematic

6.11 Details for Figure 6.10: Typical EOL for MV VFD Transformer Protection Schematic

6.11.1 Low Overcurrent Setting: (I >)

6.11.2 High Overcurrent Setting: (I >>)

6.11.3 Conclusion of Calculation

Changes to Motor Operating Characteristics and Dynamics that can Impact Protection

Changes to Motor Operating Characteristics and Dynamics that can Impact Protection

6.12 Power System Dynamic Calculations

6.13 Protective Relay Coordination and Discrimination Study

7 Power Quality: Harmonics

7.0 Introduction

7.1 Solid-State Devices Carrier Frequency

7.2 MIL-STD-1399 Requirements

7.3 IEEE STD 519 Requirements (1992 and 2014 Versions)

7.3.1 Total Harmonic Distortion (THD)

7.3.2 Total Demand Distortion (TDD): Current Harmonics

7.4 Calculate the RMS Harmonic Voltage Due to the Respective Harmonic Current

7.5 Current Harmonic Matters

7.6 Harmonic Numbering

7.7 DNV Regulation: Harmonic Distortion

7.8 Examples of Typical Shipboard Power System Harmonic Current Calculations

7.9 Choice of 18-Pulse Drive versus 6-Pulse Drive with Active Harmonic Filter

7.10 Typical Software to Calculate Total Harmonic Distortion and Filter Applications

7.11 Harmonic Recommendations (IEEE 45.1 Partial Extract)

7.12 Harmonic Silencing and ARC Prevention (Curtsey of Applied Energy)

7.13 Applicable Power Quality Standards Include

8 Shipboard Cable Application and Verification

8.0 Introduction: Shipboard Cable Application

8.1 Cable Size Calculation Fundamentals

8.2 Shipboard Cable for ASD and VFD Applications

(a) Cable for Adjustable Speed Drive (ASD) Shipboard Application and Verification

8.3 Cable Requirements Per IEEE Std 45

8.4 Cable Shielding Guide Per IEEE Std 1143

8.5 Cable: Physical Characteristics

8.6 Cable Insulation: Typical

8.7 Cable Ampacity

8.8 Commercial Shipboard Cable Circuit Designation

8.9 Example 1: Low-Voltage 600V/1000V IEC Cable Details

8.10 Example 2: MV Voltage 8 KV/10 KV

8.11 Example 3: VFD Cable LV (600V/100) and MV VOLTAGE (8 KV/10 KV)

8.12 Ground Conductor Size

8.13 Develop Math to Calculate the Ground Conductor for Parallel Run

8.14 Cable Designation Type (Typical Ship Service Cable Symbol or Designation)

8.15 Cable Color Code: Shipboard Commercial Cable

8.16 ASD (VFD) Cable Issues for Shipboard Application

8.17 ABS Steel Vessel Rule: Part 4, Chapter 8, Section 4: Shipboard Cable Application

8.18 Grounding Conductor Size: for Cable Rated 2 KV or Less for Single Run

9 Grounding, Insulation Monitoring Design, and Verification

9.0 Introduction

9.1 System Grounding Per IEEE 45

9.1.1 Shipboard LV Power System Grounding IEEE 45 Recommendations (See Figures 9.1 and 9.2)

9.2 Selection of High-Resistance Grounding (HRG) System

9.3 IEEE 142 Ground Detection Requirements

9.4 IEC Requirements: Insulation Monitoring System

9.4.1 Insulation Monitoring

9.4.2 Insulation Monitoring System for Grounded AC Systems with VFD System

9.5 System Capacitance to Ground Charging Current Calculation (Taken From IEEE 142 Figs. 1.6 and 1.9)

9.6 Total System Capacitance Calculation

9.7 Calculate Capacitive Charging Current: (for a Typical Installation)

9.8 Capacitive Charging Current Calculation: Sample Calculation

9.8.1 Iccc Calculation for Generators 12,000 kVA, 6600V, 3-Phase, 3-Wire—Total 4

9.8.2 Iccc Calculation for Transformers

9.8.3 Cables 8 kV—(4/0 AWG) (T-212) Cable Three Core

9.8.4 Total Capacitive Charging Current

9.8.5 Grounding Transformer Size Calculation

9.8.6 Grounding Resistor Size Calculation

9.9 Grounding Resistor Selection Guideline Per IEEE STD 32-1972

9.10 Grounding Resistor Duty Rating

9.11 Zigzag Grounding Transformers: IEEE STD 142 Section 1.5.2

9.12 Rating and Testing Neutral Grounding Resistors: IEEE STD 32-1972

9.13 Voltage Stabilizing Ground Reference (VSGR) Phaseback for Ground Detection (Curtsey of Applied Energy)

9.13.1 Typical HRG Elementary Diagrams Are Very Close to the Voltage Stabilizing Ground Reference (VSGR) Phaseback Unit, Looking Alike Phasebacks Function Is Exactly Opposite to the HRG

9.13.2 Phaseback Voltage Stabilizing Ground Reference Addresses and Solves the Following Issues

HRG-Neutral Grounding Transformer Example—6.6kV System (Typical)

HRG-Neutral Grounding Resistor—120V (Typical)

9.14 HRG Versus VSGR

9.15 Shipboard Ground Detection System Recommendations

References

10 Shore Power LV and MV Systems

10.0 Introduction

10.1 LV Shore Power System

10.2 MV (HV) Shore Power System

10.3 Low-Voltage Shore Power System

10.4 Four-Wire Grounded System LV Shore Power Connections

10.5 Medium-Voltage Shore Power System (MV)

10.6 Extract from IEC/ISO/IEEE 80005-1 Part 1: High-Voltage Shore Connection (HVSC) Systems HV Shore Power Requirements (Shore to Ship Power Quality and Protection Requirements)

IEEE-IEC 80005-1 Section 5.2 Quality of HV Shore Supply

IEC 800050-1 Section 4.8 System Study and Calculations

11 Smart Ship System Design (S3D) and Verification

11.0 Introduction

11.1 Virtual Prototyping for Electrical System Design

11.2 Electrical Power System Smart Ship System Design Failure Mode and Effect Analysis

11.3 Marine Technology Society (MTS) Guidelines for DP Vessel Design Philosophy: Guidelines for MODU DP System and Commercial Ships

11.4 Additional Marine Technology Society (MTS) Requirements Applicable for Ship Design: USCG Recognized MTS Requirements

11.5 Condition-Based Maintenance

11.6 FMEA Objectives: S3D Concept

11.7 Additional S3D Process Safety Features

12 Electrical Safety and Arc Flash Analysis

12.0 Introduction

12.1 Injuries Result from Electrical-Current Shorts

12.2 General Safety Tips for Working with or Near Electricity

12.3 ARC Flash Basics

12.4 Fundamentals of Electrical Arc and Arc Flash

12.5 Definitions Related to ARC Flash (Derived from NFPA 70E NEC, NFPA 70E, and IEEE STD 1580 for Shipboard Electrical Installations)

12.6 Causes of Electric ARC

12.7 Incident Energy

12.8 Incident Energy at ARC Flash Protection Boundary

12.9 The Flash Protection Boundary

12.10 Electrical Hazards: ARC Flash with Associated Blast and Shock

12.11 Shock Hazard

12.12 Hazard/Risk Categories (Derived from NFPE-70E)

12.12.1 Hazard/Risk Category: Description (HRC-0)

12.12.2 Hazard/Risk Category: Description (HRC-1)

12.12.3 Hazard/Risk Category: Description (HRC-2)

12.12.4 Hazard/Risk Category: Description (HRC-3)

12.12.5 Hazard/Risk Category: Description (HRC-4)

12.13 Shipboard Electrical Safety Compliance Chart per NFPA 70E 2012 Table 130.7.C.9

12.14 ARC Flash: OSHA Requirements (29 CFR 1910.333)

12.15 ARC Flash: National Electrical Code (NEC) Requirements

12.16 Arc Flash: NFPA 70E 2012 Requirements

12.17 Arc Flash Boundary: NFPA 70E

12.18 Low-Voltage (50 V–1000V) Protection (NFPA 70E 130.3 (A1))

12.19 Medium-Voltage (1000V and Above) (NFPA 70E 130.3 (A2))

12.20 Arc Flash: IEEE 1584 Requirements and Guidelines

12.21 Arc Flash: Circuit Breaker Time Currect Coordination—Overview

12.22 ARC Flash Calculation Analysis and Spreadsheet Deliverables

12.22.1 For Shipboard Arc Flash Analysis the Following Should Be Included

12.23 Methods of Developing Analysis

12.23.1 Coordination Study

12.24 Fault Current Analysis to Ensure Power System Component Protection Characteristics

12.25 Fault Current Calculation: Approximation for Arc Flash Analysis

12.26 Shipboard Fault Current Calculation Guidelines (per USCG Requirements)

12.27 Example Shipboard Fault Current Calculations (per USCG Requirements CFR 111-52-3(B) & (C))

12.28 Shipboard Power System Short-Circuit Current Calculation (Refer to US Navy Design Data Sheet 300-2 for Details)

12.29 Fault Current and ARC Flash Analysis as Required by NFPA 70E

12.30 Fault Current and ARC Flash Analysis Guide by IEEE 1584

12.31 Electrical Safety and ARC Flash Labeling (NFPA 70E)

12.32 Arc Flash Protection-Boundary

12.33 Sample ARC Flash Calculations: Spreadsheet—Excel Type

12.33.1 NFPA 70E 2009 Equation D.5.2 (A) for Arc Flash Calculation

12.34 Low-Voltage (50 V–1000V) Protection (NFPA 70E 130.3 (A1))

12.35 Medium Voltage (1000V and Above) (NFPA 70E 130.3 (A2))

12.36 IEEE 1584-Based Arc Flash Calculations

12.36.1 IEEE 1584: Incident Energy Exposure

12.36.2 IEEE 1584: Arcing Current Calculation: Up to 1000V Systems

12.36.3 IEEE 1584: Arcing Current Calculation for 1kV TO 15kV

12.36.4 IEEE 1584: Flash Protection Boundary Calculation (DB)

12.36.5 IEEE 1584: Flash Protection Boundary

12.36.6 IEEE 1584: Level of PPE

12.36.7 IEEE-1584: Equipment Class

12.36.8 IEEE 1584: Distance Exponent

12.36.9 IEEE 1584: Arc Duration/Total Arc Clearing Time

12.36.10 IEEE 1584: Available Three-Phase Bolted Fault Current

12.36.11 IEEE 1584: Predicted Three-Phase Arcing Current

12.37 Sample Shipboard Arc Flash Calculation Project

12.37.1 General

12.37.2 Short-Circuit Study

12.37.3 Protective Device Coordination Study

12.37.4 Arc Flash Hazard Study

12.37.5 Analysis

12.37.6 Report

12.38 Fast-Acting Arc Management System: Arc Flash Mitigating Hardware Driven Time

LIMITING FEATURES:

12.39 Guidelines for Shipboard Personnel

Glossary

Index

EULA

The users who browse this book also browse


No browse record.