Publisher: Edp Sciences
E-ISSN: 2100-014x|153|issue|02008-02008
ISSN: 2100-014x
Source: EPJ Web of Conference, Vol.153, Iss.issue, 2017-09, pp. : 02008-02008
Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.
Abstract
After fission or fusion reactor shutdown the activated structure emits decay photons. For maintenance operations the radiation dose map must be established in the reactor building. Several calculation schemes have been developed to calculate the shutdown dose rate. These schemes are widely developed in fusion application and more precisely for the ITER tokamak. This paper presents the rigorous-two-steps scheme implemented at CEA. It is based on the TRIPOLI-4® Monte Carlo code and the inventory code MENDEL. The ITER shutdown dose rate benchmark has been carried out, results are in a good agreement with the other participant.
Related content
Advances in Monte-Carlo code TRIPOLI-4®’s treatment of the electromagnetic cascade
EPJ Web of Conference, Vol. 170, Iss. issue, 2018-01 ,pp. :
EPJ Web of Conference, Vol. 153, Iss. issue, 2017-09 ,pp. :
A Monte-Carlo Benchmark of TRIPOLI-4® and MCNP on ITER neutronics
EPJ Web of Conference, Vol. 153, Iss. issue, 2017-09 ,pp. :