Author: LIN RUAN GUOBIAO GU XINDONG TIAN
Publisher: Taylor & Francis Ltd
ISSN: 1532-5016
Source: Electric Power Components and Systems, Vol.33, Iss.2, 2005-01, pp. : 145-158
Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.
Abstract
This article aims to present an effective calculating method for computing the temperature distribution along the length of hollow conductors in the stator bars of evaporative cooling hydro-generators. A kind of partition of flow patterns was adopted and the corresponding convective heat exchange coefficients were calculated according to the different flow patterns. Comparative results show that the calculating temperature distribution is in accord with the experimental measurement to about 10% relative error. On the whole, this calculating model is reliable and can be used in the applied engineering field.
Related content