Author: Little M. P. Muirhead C. R.
Publisher: Informa Healthcare
ISSN: 1362-3095
Source: International Journal of Radiation Biology, Vol.74, Iss.4, 1998-10, pp. : 471-480
Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.
Abstract
Purposes : To investigate the evidence for a threshold in the cancer dose-response curve. Materials and methods : Japanese atomic bomb survivor cancer mortality data, based on follow-up to 1990, was used, taking account of random errors in DS86 dose estimates. Results : For all solid cancers analysed together, there is a significant positive dose response (two-sided p 0.05) if all survivors who received 0.5Sv are considered, but the significance vanishes if doses of 0.2 Sv are considered; the same is also true for leukaemia. For solid cancer mortality there is no indication of curvilinearity in the dose response: no statistically significant improvement in fit to a linear relative risk model is provided by addition of quadratic or threshold dose terms. If a relative risk model with a threshold (the dose response is assumed linear above the threshold) is fitted to solid cancer mortality data, the best estimate of the threshold is 0.00 Sv (95% CI 0.00-0.13). If a linearquadratic-threshold model is used the best estimate of the threshold is 0.00 Sv (95% CI 0.00-0.15). For leukaemia mortality there is highly statistically significant upward curvature in the dose response. In particular, if a relative risk model with a threshold (the dose response is assumed linear above the threshold) is fitted to the leukaemia data, the best estimate of the threshold is 0.16Sv (95% CI 0.05-0.40) (twosided p 0.001 for test of departure of threshold from 0). However, there is no evidence for a threshold effect (two-sided p 0.16) when a quadratic term is included in the dose response: the best estimate of threshold in this case is 0.09Sv (95% CI 0.00-0.29). Moreover, addition of a quadratic term improves the fit of a linear-threshold model at borderline levels of statistical significance (two-sided p 0.07). Therefore, the most parsimonious description of the leukaemia dose response is provided by a linear-quadratic function of dose. Conclusions : There is no evidence of threshold-type departures from the linear-quadratic dose response either for solid tumours or for leukaemia in the Japanese atomic bomb survivor mortality data.
Related content


By Little M. P.
International Journal of Radiation Biology, Vol. 78, Iss. 11, 2002-11 ,pp. :




By Little M. P. Muirhead C. R.
International Journal of Radiation Biology, Vol. 76, Iss. 7, 2000-07 ,pp. :


By Little M. P.
International Journal of Radiation Biology, Vol. 76, Iss. 10, 2000-10 ,pp. :