The fluorimetric determination of mercury ions with o-vanillin-8-aminoquinoline (OVAQ) in aqueous solutions was investigated. Hg(II) could react with the fluorescent reagent OVAQ (λex/em = 278/314 nm) to form a nonfluorescent complex in an ethanol-water medium of pH 6.00. The linear range of the proposed method was from 2.5 to 80 μg/L, and the detection limit was 0.80 μg/L. The interferences of 24 foreign ions were also studied. The method was successfully applied to the determination of Hg(II) in sludge.