Effects of Different Compression Techniques on Diagnostic Accuracies of Breast Masses on Digitized Mammograms

Author: Liang Zhigang   Du Xiangying   Liu Jiabin   Yang Yanhui   Rong Dongdong   Yao Xinyu   Li Kuncheng  

Publisher: Blackwell Publishing

ISSN: 0284-1851

Source: Acta Radiologica, Vol.49, Iss.7, 2008-01, pp. : 747-751

Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.

Previous Menu Next

Abstract

Background: The JPEG 2000 compression technique has recently been introduced into the medical imaging field. It is critical to understand the effects of this technique on the detection of breast masses on digitized images by human observers. Purpose: To evaluate whether lossless and lossy techniques affect the diagnostic results of malignant and benign breast masses on digitized mammograms. Material and Methods: A total of 90 screen-film mammograms including craniocaudal and lateral views obtained from 45 patients were selected by two non-observing radiologists. Of these, 22 cases were benign lesions and 23 cases were malignant. The mammographic films were digitized by a laser film digitizer, and compressed to three levels (lossless and lossy 20:1 and 40:1) using the JPEG 2000 wavelet-based image compression algorithm. Four radiologists with 10-12 years' experience in mammography interpreted the original and compressed images. The time interval was 3 weeks for each reading session. A five-point malignancy scale was used, with a score of 1 corresponding to definitely not a malignant mass, a score of 2 referring to not a malignant mass, a score of 3 meaning possibly a malignant mass, a score of 4 being probably a malignant mass, and a score of 5 interpreted as definitely a malignant mass. The radiologists' performance was evaluated using receiver operating characteristic analysis. Results: The average Az values for all radiologists decreased from 0.8933 for the original uncompressed images to 0.8299 for the images compressed at 40:1. This difference was not statistically significant. The detection accuracy of the original images was better than that of the compressed images, and the Az values decreased with increasing compression ratio. Conclusion: Digitized mammograms compressed at 40:1 could be used to substitute original images in the diagnosis of breast cancer.