Abstract
The performance of a cooled Be compound refractive lens (CRL) has been tested at the Advanced Photon Source (APS) to enable vertical focusing of the pink beam and permit the X‐ray beam to spatially overlap with an 80 µm‐high low‐density plasma that simulates astrophysical environments. Focusing the fundamental harmonics of an insertion device white beam increases the APS power density; here, a power density as high as 500 W mm−2 was calculated. A CRL is chromatic so it does not efficiently focus X‐rays whose energies are above the fundamental. Only the fundamental of the undulator focuses at the experiment. A two‐chopper system reduces the power density on the imaging system and lens by four orders of magnitude, enabling imaging of the focal plane without any X‐ray filter. A method to measure such high power density as well as the performance of the lens in focusing the pink beam is reported.
Related content


One-dimensional criticism: a Marcusean reflection on Habermas's critical theory 1
The European Legacy, Vol. 9, Iss. 4, 2004-08 ,pp. :


Large‐aperture prism‐array lens for high‐energy X‐ray focusing
JOURNAL OF SYNCHROTRON RADIATION (ELECTRONIC), Vol. 23, Iss. 5, 2016-09 ,pp. :