Author: Benaissa A.
Publisher: Edp Sciences
E-ISSN: 2100-014x|29|issue|00007-00007
ISSN: 2100-014x
Source: EPJ Web of Conference, Vol.29, Iss.issue, 2012-06, pp. : 00007-00007
Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.
Abstract
Piezo-pumps, in the last decade, have received extensive attention because of their potential applications in biomedical devices, biological and chemical analysis, micro-electronics cooling and space exploration. In this paper an analytical model is developed to analysis the parameters effect on the pump flow. The micro-pump driven by piezostack (PZT alloy multilayer) as actuator is studied as function size and working middle. This one is compared with SCMCP pump actuated by PZT alloy as piezomembrane. The flow change as a function frequency, the chamber diameter and control voltage are analyzed. The simulation results obtained with two different liquids (water and blood) as working middle are discussed and compared with experimental results. The results are satisfactory.
Related content






Analysis of cavitation behaviour in a centrifugal pump
IOP Conference Series: Earth and Environmental Science, Vol. 15, Iss. 6, 2012-11 ,pp. :


Analysis of the small flying wings performances in the morphing concept
MATEC Web of conference, Vol. 121, Iss. issue, 2017-08 ,pp. :