Fire propagation over combustible exterior facades exposed to intensified flame in Japan

Author: Nishio Yuhei  

Publisher: Edp Sciences

E-ISSN: 2261-236x|46|issue|02002-02002

ISSN: 2261-236x

Source: MATEC Web of conference, Vol.46, Iss.issue, 2016-05, pp. : 02002-02002

Access to resources Favorite

Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.

Previous Menu Next

Abstract

With regard to fire safety for exterior walls of a building, fire-resistance performance is considered, according to the current Building Standard Law of Japan. And it was revealed that the fire safety is not specifically regulated from the viewpoint of reaction-to-fire performance, such as fire propagation caused by combustible materials or products installed on the exterior side of fire-resistant load-bearing walls. Actual fire incidents in the world have shown that massive façade fire could occur at the exterior side of building wall even when the wall itself is fire resistant. In previous studies of the authors, a test method of façade fire was proposed for evaluating the vertical fire propagation over an external wall within the same building [1,2]. Based on these studies, new domestic standard test method was established in Japan as JIS A 1310: 2015, “Test method for fire propagation over building façades” at the end of January 2015 [3]. But there was the argument that heat output of burner inside the combustion chamber was not sufficiently high in the previous study. In this paper, results of fire tests on combustible façades are discussed from the viewpoints of different strength of flame exposing facade. In this research, it was clearly found that JIS A 1310 with heat output of 900kW could be applicable for evaluating fire propagation behaviour over various types of combustible exterior façades.