Flue gas moisture capacity calculation at the outlet of the condensation heat recovery unit

Publisher: Edp Sciences

E-ISSN: 2261-236x|110|issue|01029-01029

ISSN: 2261-236x

Source: MATEC Web of conference, Vol.110, Iss.issue, 2017-06, pp. : 01029-01029

Access to resources Favorite

Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.

Previous Menu Next

Abstract

As a result, study equation has been obtained which determine the flue gas moisture capacity at the outlet of the condensation heat recovery unit with an error of less than 1%. It possible to at the temperature of the flue gas below the dew point and the known air-fuel ratio efficient. The equation can be used to calculate plants operating on products of gas combustion without Use of tables and programs for calculating the water-vapor saturation pressure.