Failure Analysis of Cathode Materials for Energy Storage Batteries in Overcharge Test

Author: Wang Hongwei  

Publisher: Edp Sciences

E-ISSN: 2261-236x|142|issue|01007-01007

ISSN: 2261-236x

Source: MATEC Web of conference, Vol.142, Iss.issue, 2018-01, pp. : 01007-01007

Access to resources Favorite

Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.

Previous Menu Next

Abstract

The micro-analysis of energy storage batteries in overcharge test at 20°C temperature was investigated. The results showed as follows: (1) Compared with the normal battery charge at room temperature scanning microscope maps of battery overcharge, the crystal was fractured of the positive surface when the battery was overcharging, and with the increase of experimental time, the crystal fracture is more serious, this is to say that the battery electrolyte decomposition or battery material structure could change by overcharge test. (2) Based on the XRD maps, the characteristic peak position of overcharge test of cathode materials were changed, this showed that the content of cathode material elemental has been destroyed and changed in overcharge test.