Abstract
A generic model that can cover diabatic and adiabatic distillation column configurations is presented, with the aim of providing a consistent basis for comparison of alternative distillation column technologies. Both a static and a dynamic formulation of the model, together with a model catalogue consisting of the conventional, the heat‐integrated and the mechanical vapor recompression distillation columns are presented. The solution procedure of the model is outlined and illustrated in three case studies. One case study being a benchmark study demonstrating the size of the model and the static properties of two different heat‐integrated distillation column (HIDiC) schemes and the mechanical vapor recompression column. The second case study exemplifies the difference between a HIDiC and a conventional distillation column in the composition profiles within a multicomponent separation, whereas the last case study demonstrates the difference in available dynamic models for the HIDiC and the proposed model. © 2015 American Institute of Chemical Engineers AIChE J, 61: 4251–4263, 2015