Cement Composite Reinforced with Synthetic Fibers: Comparison of Three-Point and Four-Point Bending Test Results

Publisher: Trans Tech Publications

E-ISSN: 1662-7482|2016|827|332-335

ISSN: 1660-9336

Source: Applied Mechanics and Materials, Vol.2016, Iss.827, 2016-03, pp. : 332-335

Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.

Previous Menu Next

Abstract

Presented article deals with the influence of PET fiber production on the bending strength of cement-based composite when incorporated into the fresh mortar, and comparison of results of 3-point and 4-point bending test. Cement paste samples were reinforced with 2 wt. % of primary or recycled PET fibers. The bending test was performed on prismatic samples with dimension of 40 × 40 × 160 mm. It was found that samples with recycled PET fibers, compared to primary ones, exhibit a decrease in bending strength. In the case of 4-point bending tests, the samples with recycled PET fibers exhibited higher bending strength than reference samples without any fibers. However, in the case of 3-point bending tests, the samples with recycled PET fibers had lower bending strength than the reference ones. The results suggest that recycled PET fibers could be used as an alternative to reinforce cement-based composites.