Author: East James
Publisher: Springer Publishing Company
ISSN: 0938-7994
Source: European Radiology, Vol.18, Iss.9, 2008-09, pp. : 1910-1917
Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.
Abstract
The effect of field of view on mucosal visualisation and reader efficiency during three-dimensional endoluminal CT colonography (CTC) was investigated. Twenty CTC datasets were reviewed at standard 90-degree and “wide” 140-degree viewing angles using customised viewing software (V3D colon; Viatronix), which listed number and size of missed mucosal areas (“missed regions tool”) and percentage mucosal visualisation. We compared: (1) unidirectional and bidirectional flythrough using 140- versus 90-degree viewing angles; (2) reader analysis time comparing unidirectional 140-degree flythrough versus bidirectional 90-degree flythrough; (3) paired image snapshots of 12 polyps taken at each field of view were reviewed to assess conspicuity. All patients underwent conventional colonoscopy. Bidirectional 140-degree review reduced the numbers of missed areas by between eight- and 40-fold depending on size category, including those >1,000 mm2, compared with standard 90-degree bidirectional flythrough (
Related content










Flat lesions in CT colonography
Abdominal Imaging, Vol. 35, Iss. 5, 2010-10 ,pp. :