Analysis of the Chloroacetanilide Herbicides in Water Using SPME with CAR/PDMS and GC/ECD

Author: Hwang Ying-Ming   Wong Yih-Gang   Ho Wu-Hsiung  

Publisher: AOAC International

ISSN: 1944-7922

Source: Journal of AOAC International, Vol.88, Iss.4, 2005-07, pp. : 1236-1241

Disclaimer: Any content in publications that violate the sovereignty, the constitution or regulations of the PRC is not accepted or approved by CNPIEC.

Previous Menu Next

Abstract

The solid-phase microextraction (SPME) technique using a 75 mm film of carboxen/polydimethylsiloxane was applied to the analysis of chloroacetanilide herbicides (acetochlor, alachlor, butachlor, metolachlor, and propachlor) residues. The feasibility of SPME with gas chromatography electron capture detection analysis has been evaluated. The effects of experimental parameters such as magnetic stirring, salt addition, humic acid addition, pH value, and extraction time, as well as desorption temperature and time, were investigated. Analytical parameters such as linearity, repeatability and limit of detection were also evaluated. The inhibition of humic acid to the extraction of chloroacetanilide herbicides was observed. A standard addition method for calibration was recommended to reduce deviations caused by matrix interferences. The proposed method provided a simple and rapid analytical procedure for chloroacetanilide herbicides in water with limits of detection 0.002–0.065 μg/L for deionized water, and 0.005–0.22 μg/L for farm water. The relative standard deviations (n = 5) for analyses of farm water were 7–20% for 0.5 μg/L chloroacetanilide herbicides. This application was illustrated by the analysis of sample collected from farm water in the Chung-hwa area, Taiwan.